Maintenance and cleaning steps of Dongguan bestar automatic inline checkweigher
2023-04-05 22:37:23
Maintenance and cleaning steps of Dongguan bestar automatic checkweigher
Abstract: Maintenance and cleaning of the checkweigher are mainly divided into the following four steps: 1. Clean the weighing platform of the checkweigher. After the power supply of the checkweigher is cut off, unplug the power cord. Soak the gauze and wring it dry, then dip a little neutral cleaning liquid (such as alcohol), use it to clean the weighing pan, display filter and other parts of the weighing body. 2,
The maintenance and cleaning of the automatic checkweigher are mainly divided into the following four steps:
1. Clean the weighing platform of the automatic checkweigher
After cutting off the power of the checkweigher, unplug the power cord. Soak the gauze and wring it dry, then dip a little neutral cleaning liquid (such as alcohol), use it to clean the weighing pan, display filter and other parts of the weighing body.
2. Level correction
Check whether the scale body of the automatic checkweigher is normal; if it is tilted, you need to adjust the feet to place the scale in the center position.
3. Clean the printer (if the equipment is equipped with a printer, the equipment without a printer can ignore this step)
Cut off the power, open the plastic door on the right side of the scale body, hold the plum blossom handle on the outside of the printer, and drag the printer out of the scale body. Press the reed on the front of the printer, loosen the print head, and gently wipe the print head with the special print head cleaning pen included in the scale accessory. After cleaning and wiping, cover the pen cap to prevent the cleaning fluid from evaporating in the pen, and then wait for two minutes. After the cleaning liquid on the print head is fully evaporated, close the print head, push the printer back into the scale body, close the plastic door, power on and test, and it can be used normally after the print is clear.
4. Initialization
The automatic checkweigher has the functions of zero tracking and zero reset at power-on, which can clear foreign objects on the weighing pan after power-on, ensuring that the scale is powered on when there is no wind around. If there is a little weight display after power-on, you can press the "clear" button on the keyboard Restore the scale to the zero position.
English
Español